FarDriver Motor Specs: Pole Pairs & Sensors
Look up motor configuration information for FarDriver controllers, including magnetic pole pairs, sensor types and motor tuning references.
These controllers push hundreds of amps. Always put the wheel off the ground before applying throttle during setup, disconnect the battery before touching phase or battery leads, and use a precharge resistor or a breaker with precharge when connecting the pack. Never plug or unplug a Bluetooth dongle with the controller powered on. Tuning past your motor's, battery's or BMS's limits can destroy hardware or start a fire — you're responsible for what you set. Big-power settings are for off-road and closed-course use.
LMotor tuning specs
The controller can't guess what it's bolted to. Six values come off the motor, not out of a tune — get them wrong and the motor won't spin, won't self-learn, reads double speed, or cooks itself while everything looks fine on screen.
What the controller needs from the motor
| FarDriver setting | Where the number comes from | What happens if it's wrong |
|---|---|---|
| Position sensor | Hall or encoder — and for encoders, the count (e.g. 4096) | Motor won't run, or runs rough and hot |
| Pole pairs | Motor spec. Sotion and most QS mid drives are 5 (QS180 90H is 4); the 12" hub motors here are 15–16, and the split hubs are 20 | Won't rotate at all on encoder motors; speed display and the whole RPM current curve are scaled wrong on hall motors |
| Temp sensor type | Motor spec — KTY84/130, KTY83/122 or 10K NTC are the common ones | No thermal protection at all, or a permanent false over-temp |
| Rated voltage | Your pack, not the motor — but must not exceed what the motor is wound for | Over-volting shortens motor life; under-setting caps your power |
| Rated speed & max speed | Motor's rated RPM; the gap between them is your field-weakening depth | Too big a gap = MOE/OVER faults and a motor that heats without doing work |
| Max phase & line current | Lower of: what the motor can take, what the pack can give, what the controller is rated for | Melted windings, tripped BMS, or a controller that limits constantly |
If the motor has a KTY84/130 in it and the controller is set to NTC, the reading is meaningless and thermal protection does nothing. Set the controller to the same sensor the motor actually has — and if the motor has no sensor, set it to None rather than leaving a random type selected.
Every Sotion mid drive uses a 10K NTC — FW11, FW22, FW23, GTS11, GTS11-C and GTS35 alike. Set 6-NTC in the app for any of them.
Kunray and QS motors use KTY sensors, and the app lists two — 3-KTY is the KTY83-122, 5-KTY is the KTY84-130. Start with 3-KTY on Kunray and QS motors; some QS mid drives ship with either sensor. To check you picked right, look at the motor temperature on the Graph page with the bike cold — it should read about the same as the MOSFET temperature. If it reads wildly high, low or pinned, try the other option.
The whole list as the app shows it: 0-None · 3-KTY (KTY83-122) · 5-KTY (KTY84-130) · 6-NTC (NTC 10K). Pick the one your motor actually has — the number is what you select, the part name is what's inside the motor.
The hub motors use CACU — there's no physical probe, so the controller estimates motor temperature from the load. That estimate is only as good as the rated power you entered, so set rated power correctly on these or the thermal protection is guessing.
Motors we sell — the numbers you'll need
| Motor | Sensor · poles · temp | Power | RPM | Controller | Notes |
|---|---|---|---|---|---|
| Sotion FW11 | Hall · 5 pp · NTC 10K | 5 / 10 kW | 10,000 | ND72450 | 72 V · #35 11T sprocket |
| Sotion FW22 | Hall · 5 pp · NTC 10K | 12 / 25 kW · 57 Nm | 7,000 / 10,000 | ND72890 | 900 A phase · Valtinsu EM-5 / Yozma IN10 |
| Sotion FW23 | Encoder · 5 pp · NTC 10K | 8 / 16 kW | 10,000 | ND72680b | 72 V · Tuttio Soleil01 |
| Sotion GTS11 | Hall · 5 pp · NTC 10K | 7 / 15 kW | 11,000 | ND72680 | 72 V · 700 mm phase leads |
| Sotion GTS11-C v3 | Hall · 5 pp · NTC 10K | 9 kW | 10,000 | ND72680 | 72 V · direct drive · 219H 12T · IP67 · air cooled · ≥90% eff · EBox Dragster, MXR, 48 V Mototec |
| Sotion GTS35 | Hall · 5 pp · NTC 10K | 20 / 40 kW | 10,000 | ND961200 | 96 V · 19 / 80 Nm · 1200 A peak phase · mid mount · φ190×210 mm, 15 kg · 520 13T |
| Kunray MY1020+ | Hall · 3 pp · KTY83-122 | 7–8 kW | 10,000 | ND72300 | 48 V or 72 V · 25H sprocket included |
| Kunray KR5V v2 | Hall · 5 pp · KTY83-122 | 5 kW | 10,000 | ND72450 | 72 V · V-magnet BLDC · reverse-thread shaft nut |
| Kunray KR10 | Encoder · 5 pp · KTY84-130 | 6.5 / 12.5 kW | 10,000 | ND72680b | Tuttio Soleil 01 fitment |
| QS90 | Hall · 5 pp · KTY83-122 | 5 kW | 10,000 | ND72300 | 428 sprocket |
| QS90 "R" custom race | Hall · 5 pp · KTY83-122 | 8–9 kW | 10,000 | ND72340 | 72 V · 50+ mph · optional #35 race sprockets |
| QS120 | Hall · 5 pp · 3-KTY | 2 kW | 7,500 | ND72240 | 72 V · 428 14T |
| QS120 v3 | Hall · 5 pp · KTY83-122 | 8–14 kW | 10,000 | ND72450 or ND72680 | Gear-reduction mid drive · 428 14T |
| QS138 v3 70H | Hall · 5 pp · 3-KTY | 3 kW | 10,000 | ND72300 | 72 V · 1:2.35 reduction · 428 14T |
| QS165 10 kW | Hall · 5 pp · KTY83-122 | 20–30 kW | 12,000 | ND72680 · ND721000 | 428 14T |
| QS165 v2 | Hall · 5 pp · KTY83-122 | 15–22 kW | 10,000 | ND72680 | 428 14T |
| QS165 v2 35H | Hall · 5 pp · KTY83-122 | 5 kW | 10,000 | ND72450 | 72 V · 32" phase leads, 28" hall leads |
| QS165 v3 60H | Hall · 5 pp · KTY83-122 | 12 kW | 10,000 | ND72850 | 72 V · 1:2.37 reduction · 428 14T |
| QS180 90H | Enc 4096 · 4 pp · PTC | 8 / 16 kW · 100 Nm | 10,000 | ND72890b | 72 V · 520 13T |
| QSJ155A-36 hairpin | Encoder · 5 pp · KTY83-122 | 5 kW | 10,000 | ND72450b | 72 V · 1:2.94 reduction · mount plates included |
| 12" split hub (8" motor) 48 V | Hall · 20 pp · CACU | 2 kW | 1,500 | ND72240 | Single phase input · runs 48–72 V |
| 12" split hub (8" motor) 72 V | Hall · 20 pp · CACU | 5 kW | 1,500 | ND72450 | Single phase input · runs 48–72 V |
| 12" hub (8" motor) 5500 W | Hall · 15 pp · CACU | 5.5 kW · 85 Nm | 100 km/h | ND72530 | 72 V · dual phase inputs · 60H magnets |
| 12" hub (8" motor) 5000 W — HM | Hall · 15 pp · CACU | 5 kW | 2,106 | ND72450 | 72 V · dual phase inputs · 60H magnets |
| 12" Lonnyo R4 (8" motor) | Hall · 16 pp · NTC3950b 10K | 5.5 kW | 3,000 | ND72530 | 72 V · single phase · 80 mm magnets · 147 mm stator |
| 14" hub (10" motor) | Hall ×2 · 20 pp · CACU | 5 kW | 1,500 | ND72450 | 72 V · single phase input · runs 48–72 V |
Count pole pairs, not poles: a motor described as 40-pole is 20 pole pairs. The two apps can also present this differently, so a figure copied from one may read double or half in the other. If your speedo reads exactly twice or exactly half what it should after switching apps, this is the reason. Always set the number in the app you are actually using rather than carrying it across.



Other common motors
| Motor | Pole pairs | Temp sensor |
|---|---|---|
| MY1020 (original, non-plus) | 3 | 3-KTY |
| EC4P and EC4P Lite | 4 | 3-KTY or 5-KTY |
| Sotion FW01 | 5 | 6-NTC |
| MotoTec mid drive | 5 | 0-None |
| EGO mini bike stock hub motor | 16 | 6-NTC |
| B1 Bomb Moto | 5 | 0-None |
Replacement hall & encoder sensors
A motor hall fault — one beep — usually means wiring, wrong pole pairs, or a failed sensor. Once you've ruled out the first two, the sensors themselves are a cheap repair, and on most of these motors they come as a complete PCB you swap in. The same part can also convert a motor between hall and encoder.


| Part | Fits | |
|---|---|---|
| Sotion motor PCB replacement / swap | GTS01, GTS11, FW01, FW02, FW01 Pro, FW22, FW23 — also converts hall ↔ encoder | View |
| Sotion hall sensors | FW11 motor — individual hall sensors rather than a whole board | View |
| QS mid motor PCB replacement | QS mid drives, hall or encoder. Check the photo against your board — we stock the newer hall version | View |
| Hall sensor wire adapter | Furukawa to 2.3 mm — joins hub motor hall leads to a FarDriver harness | View |
| Replacement wire harness | FarDriver controllers — for a chewed or cut harness | View |
| Motor / controller / throttle tester | Proves halls, throttles and 5 V supply in seconds — use it before buying sensors | View |
| Motor end cap sets | Repair sets for FW11, GTS11 and KR5V |
Wrong pole pairs throws the same hall fault as a dead sensor, and it's free to fix. Check the pole-pair number for your motor in the table above, then use the tester to confirm the halls are actually dead before ordering parts.
Reading a QS Motor part number
The numbers
QS names its motors by stator diameter in millimetres — 90, 120, 138, 155, 165, 180 for mid drives; 205, 260, 273 for the big hub motors. The H number is the stator/magnet height, again in mm: 35H, 45H, 50H, 60H, 70H, 90H.
Bigger diameter = more torque. Bigger H = more copper and iron in the same diameter, so more continuous power and less heat. A QS165 v3 60H is a 165 mm stator, 60 mm tall.
V1, V2, V3, V4
QS builds the same motor at four levels. Straight from QS's own documentation:
- V1 — iron holder, one hall plug, 84–87% efficient
- V2 — aluminium holder, two hall plugs (one spare), more copper, 86–88%
- V3 — 16 pole pairs, wider laminations, thicker copper, wider magnets, 88–92%. More torque at the same current and it runs cooler
- V4 — better silicon steel, larger slots, more copper, upgraded halls and magnets. Coolest and most stable of the four under heavy load and over-voltage
What QS says about running their motors hard
Peak is about double rated
A 3 kW V2 or V3 motor will make roughly 6 kW peak. That's a burst figure — sustained, it's a heat problem, not a power figure.
Max Line Current is a battery number
Set it from your pack's maximum continuous discharge rating — not the peak or burst figure on the label. For the Amorge packs we sell: 72V 32Ah is 200 A, 72V 24Ah is 150 A, 72V 20Ah is 100 A. Check your own pack's rating before entering anything.
Their current advice at 72 V
QS suggests a maximum of 70–80 A battery current for general use — the most stable setup and the longest motor life. Riders commonly run 150 A; the motor will do it, but held there it gets hot and can burn. That's a line-current ceiling worth starting from.
Fit a thermal probe
QS strongly recommends a temperature sensor (KTY83/122, KTY84/130 or a 10K NTC, model MF58-103F3950) so the controller can protect the motor from the inside. Set the matching type in the app or it does nothing.
Over-volting works, with a cost
A 3 kW motor doing 80 km/h at 72 V might reach 100 km/h at 96 V, with continuous output well past its 3 kW rating. QS calls this abusing usage: it runs, life is shorter, and V3/V4 handle it better than V2.
Hall plugs
V2 and V3 hub motors have two hall plugs — the second is a spare. If a hall reading goes bad, try the other plug before pulling the motor apart. V1 motors have only one.
Expected life
QS puts general usage at 2–5 years, 5–7 in good conditions. Testing and abuse shorten that, and heat is what does the damage — which is why the temp sensor and current ceilings matter more than any other setting.
Worked example — a QS165 v3 60H on 72 V
- Position sensor: Hall 120°.
- Pole pairs: from the motor's spec — a QS V3 hub is 16; a geared mid drive is not the same number, so check before you assume.
- Temp sensor: set to whatever is physically in the motor, or None.
- Rated voltage: 72 V.
- Rated power: 12,000 W from the listing.
- Max line current: start conservative — QS's own guidance is 70–80 A at 72 V for long life. Raise from there while watching motor temperature.
- Max phase current: below the controller's rating and below what the motor is happy with. Raise in 10–15% steps.
- Transmission ratio: this motor is 1:2.37 geared, so the speedo needs that ratio and the real pole-pair count to read correctly.
- Run self-learning with the wheel off the ground, then re-check the direction.