Independent technical resource

FarDriver Motor Specs: Pole Pairs & Sensors

Look up motor configuration information for FarDriver controllers, including magnetic pole pairs, sensor types and motor tuning references.

Read this first

These controllers push hundreds of amps. Always put the wheel off the ground before applying throttle during setup, disconnect the battery before touching phase or battery leads, and use a precharge resistor or a breaker with precharge when connecting the pack. Never plug or unplug a Bluetooth dongle with the controller powered on. Tuning past your motor's, battery's or BMS's limits can destroy hardware or start a fire — you're responsible for what you set. Big-power settings are for off-road and closed-course use.

LMotor tuning specs

The controller can't guess what it's bolted to. Six values come off the motor, not out of a tune — get them wrong and the motor won't spin, won't self-learn, reads double speed, or cooks itself while everything looks fine on screen.

What the controller needs from the motor

FarDriver settingWhere the number comes fromWhat happens if it's wrong
Position sensorHall or encoder — and for encoders, the count (e.g. 4096)Motor won't run, or runs rough and hot
Pole pairsMotor spec. Sotion and most QS mid drives are 5 (QS180 90H is 4); the 12" hub motors here are 15–16, and the split hubs are 20Won't rotate at all on encoder motors; speed display and the whole RPM current curve are scaled wrong on hall motors
Temp sensor typeMotor spec — KTY84/130, KTY83/122 or 10K NTC are the common onesNo thermal protection at all, or a permanent false over-temp
Rated voltageYour pack, not the motor — but must not exceed what the motor is wound forOver-volting shortens motor life; under-setting caps your power
Rated speed & max speedMotor's rated RPM; the gap between them is your field-weakening depthToo big a gap = MOE/OVER faults and a motor that heats without doing work
Max phase & line currentLower of: what the motor can take, what the pack can give, what the controller is rated forMelted windings, tripped BMS, or a controller that limits constantly
The temp sensor has to match on both ends

If the motor has a KTY84/130 in it and the controller is set to NTC, the reading is meaningless and thermal protection does nothing. Set the controller to the same sensor the motor actually has — and if the motor has no sensor, set it to None rather than leaving a random type selected.

Every Sotion mid drive uses a 10K NTC — FW11, FW22, FW23, GTS11, GTS11-C and GTS35 alike. Set 6-NTC in the app for any of them.

Kunray and QS motors use KTY sensors, and the app lists two — 3-KTY is the KTY83-122, 5-KTY is the KTY84-130. Start with 3-KTY on Kunray and QS motors; some QS mid drives ship with either sensor. To check you picked right, look at the motor temperature on the Graph page with the bike cold — it should read about the same as the MOSFET temperature. If it reads wildly high, low or pinned, try the other option.

The whole list as the app shows it: 0-None · 3-KTY (KTY83-122) · 5-KTY (KTY84-130) · 6-NTC (NTC 10K). Pick the one your motor actually has — the number is what you select, the part name is what's inside the motor.

The hub motors use CACU — there's no physical probe, so the controller estimates motor temperature from the load. That estimate is only as good as the rated power you entered, so set rated power correctly on these or the thermal protection is guessing.

Motors we sell — the numbers you'll need

MotorSensor · poles · tempPower rated / peakRPMControllerNotes
Sotion FW11Hall · 5 pp · NTC 10K5 / 10 kW10,000ND7245072 V · #35 11T sprocket
Sotion FW22Hall · 5 pp · NTC 10K12 / 25 kW · 57 Nm7,000 / 10,000ND72890900 A phase · Valtinsu EM-5 / Yozma IN10
Sotion FW23Encoder · 5 pp · NTC 10K8 / 16 kW10,000ND72680b72 V · Tuttio Soleil01
Sotion GTS11Hall · 5 pp · NTC 10K7 / 15 kW11,000ND7268072 V · 700 mm phase leads
Sotion GTS11-C v3Hall (enc. version) · 5 pp · NTC 10K9 kW10,000ND7268072 V · direct drive · 219H 12T · IP67 · air cooled · ≥90% eff · EBox Dragster, MXR, 48 V Mototec
Sotion GTS35Hall · 5 pp · NTC 10K20 / 40 kW10,000ND96120096 V · 19 / 80 Nm · 1200 A peak phase · mid mount · φ190×210 mm, 15 kg · 520 13T
Kunray MY1020+Hall · 3 pp · KTY83-122 3-KTY7–8 kW10,000ND7230048 V or 72 V · 25H sprocket included
Kunray KR5V v2Hall · 5 pp · KTY83-122 3-KTY5 kW10,000ND7245072 V · V-magnet BLDC · reverse-thread shaft nut
Kunray KR10Encoder · 5 pp · KTY84-1306.5 / 12.5 kW10,000ND72680bTuttio Soleil 01 fitment
QS90Hall · 5 pp · KTY83-122 3-KTY5 kW10,000ND72300428 sprocket
QS90 "R" custom raceHall · 5 pp · KTY83-122 3-KTY8–9 kW10,000ND7234072 V · 50+ mph · optional #35 race sprockets
QS120Hall · 5 pp · 3-KTY or 5-KTY2 kW7,500ND7224072 V · 428 14T
QS120 v3Hall · 5 pp · KTY83-122 3-KTY8–14 kW10,000 pre-gearND72450 or ND72680Gear-reduction mid drive · 428 14T
QS138 v3 70HHall · 5 pp · 3-KTY or 5-KTY3 kW10,000 pre-gearND7230072 V · 1:2.35 reduction · 428 14T
QS165 10 kWHall · 5 pp · KTY83-122 3-KTY20–30 kW12,000ND72680 min · ND721000 best428 14T
QS165 v2Hall · 5 pp · KTY83-122 3-KTY15–22 kW10,000ND72680428 14T
QS165 v2 35HHall · 5 pp · KTY83-122 3-KTY5 kW10,000ND7245072 V · 32" phase leads, 28" hall leads
QS165 v3 60HHall · 5 pp · KTY83-122 3-KTY12 kW10,000ND7285072 V · 1:2.37 reduction · 428 14T
QS180 90HEnc 4096 · 4 pp · PTC8 / 16 kW · 100 Nm10,000ND72890b72 V · 520 13T
QSJ155A-36 hairpinEncoder · 5 pp · KTY83-122 3-KTY5 kW10,000ND72450b72 V · 1:2.94 reduction · mount plates included
12" split hub (8" motor) 48 VHall · 20 pp · CACU2 kW1,500 no load · ~90 mphND72240Single phase input · runs 48–72 V
12" split hub (8" motor) 72 VHall · 20 pp · CACU5 kW1,500 no load · ~90 mphND72450Single phase input · runs 48–72 V
12" hub (8" motor) 5500 WHall · 15 pp · CACU5.5 kW · 85 Nm100 km/hND7253072 V · dual phase inputs · 60H magnets
12" hub (8" motor) 5000 W — HMHall · 15 pp · CACU5 kW2,106ND7245072 V · dual phase inputs · 60H magnets
12" Lonnyo R4 (8" motor)Hall · 16 pp · NTC3950b 10K5.5 kW3,000ND7253072 V · single phase · 80 mm magnets · 147 mm stator
14" hub (10" motor)Hall ×2 · 20 pp · CACU5 kW1,500 no load · ~90 mphND7245072 V · single phase input · runs 48–72 V
Pole pairs vs. poles — and the two apps

Count pole pairs, not poles: a motor described as 40-pole is 20 pole pairs. The two apps can also present this differently, so a figure copied from one may read double or half in the other. If your speedo reads exactly twice or exactly half what it should after switching apps, this is the reason. Always set the number in the app you are actually using rather than carrying it across.

Controller to start from is matched on pack voltage, sensor type and the motor's peak power — it's a sensible starting point, not the only controller that will work. Going bigger is fine and often better (you simply tune the current down); going smaller means the controller limits before the motor does. Ask us before ordering if your build is unusual.

Powers are the manufacturer's rated and peak figures — peak is a short burst, not something to tune for continuously. If a number here doesn't match what you see on your own motor, email info@econiccycles.com and we'll check it.

Sotion FW22 mid drive motor
Sotion mid driveFW22 — 5 pole pairs, 6-NTC, 12 kW rated
QS165 v3 60H mid drive motor
QS mid driveQS165 v3 60H — geared 1:2.37, 5-KTY
14 inch hub motor
Hub motor14" (10" motor) — 46 pole pairs, CACU, dual halls

Other common motors

Settings for motors we don't stock but that customers regularly fit a FarDriver to, taken from the FarDriver Tuning Guide v2.65.

MotorPole pairsTemp sensor
MY1020 (original, non-plus)33-KTY
EC4P and EC4P Lite43-KTY or 5-KTY
Sotion FW0156-NTC
MotoTec mid drive50-None
EGO mini bike stock hub motor166-NTC
B1 Bomb Moto50-None

Not sure of your pole pairs? Ask in the Facebook group below rather than guessing — running the wrong count is the usual cause of a motor hall fault.

Replacement hall & encoder sensors

A motor hall fault — one beep — usually means wiring, wrong pole pairs, or a failed sensor. Once you've ruled out the first two, the sensors themselves are a cheap repair, and on most of these motors they come as a complete PCB you swap in. The same part can also convert a motor between hall and encoder.

Sotion motor PCB replacement
Sotion motor PCBGTS01, GTS11, FW01, FW02, FW01 Pro (Ultra Bee), FW22, FW23 — and it swaps hall ↔ encoder
QS mid motor hall and encoder PCB replacement
QS mid motor PCBHall or encoder. Compare the photo to the board in your motor before ordering — there are two versions
PartFits
Sotion motor PCB replacement / swapGTS01, GTS11, FW01, FW02, FW01 Pro, FW22, FW23 — also converts hall ↔ encoderView
Sotion hall sensorsFW11 motor — individual hall sensors rather than a whole boardView
QS mid motor PCB replacementQS mid drives, hall or encoder. Check the photo against your board — we stock the newer hall versionView
Hall sensor wire adapterFurukawa to 2.3 mm — joins hub motor hall leads to a FarDriver harnessView
Replacement wire harnessFarDriver controllers — for a chewed or cut harnessView
Motor / controller / throttle testerProves halls, throttles and 5 V supply in seconds — use it before buying sensorsView
Motor end cap setsRepair sets for FW11, GTS11 and KR5V
Test before you buy a sensor

Wrong pole pairs throws the same hall fault as a dead sensor, and it's free to fix. Check the pole-pair number for your motor in the table above, then use the tester to confirm the halls are actually dead before ordering parts.

Reading a QS Motor part number

The numbers

QS names its motors by stator diameter in millimetres — 90, 120, 138, 155, 165, 180 for mid drives; 205, 260, 273 for the big hub motors. The H number is the stator/magnet height, again in mm: 35H, 45H, 50H, 60H, 70H, 90H.

Bigger diameter = more torque. Bigger H = more copper and iron in the same diameter, so more continuous power and less heat. A QS165 v3 60H is a 165 mm stator, 60 mm tall.

V1, V2, V3, V4

QS builds the same motor at four levels. Straight from QS's own documentation:

  • V1 — iron holder, one hall plug, 84–87% efficient
  • V2 — aluminium holder, two hall plugs (one spare), more copper, 86–88%
  • V3 — 16 pole pairs, wider laminations, thicker copper, wider magnets, 88–92%. More torque at the same current and it runs cooler
  • V4 — better silicon steel, larger slots, more copper, upgraded halls and magnets. Coolest and most stable of the four under heavy load and over-voltage

What QS says about running their motors hard

Peak is about double rated

A 3 kW V2 or V3 motor will make roughly 6 kW peak. That's a burst figure — sustained, it's a heat problem, not a power figure.

Max Line Current is a battery number

Set it from your pack's maximum continuous discharge rating — not the peak or burst figure on the label. For the Amorge packs we sell: 72V 32Ah is 200 A, 72V 24Ah is 150 A, 72V 20Ah is 100 A. Check your own pack's rating before entering anything.

Their current advice at 72 V

QS suggests a maximum of 70–80 A battery current for general use — the most stable setup and the longest motor life. Riders commonly run 150 A; the motor will do it, but held there it gets hot and can burn. That's a line-current ceiling worth starting from.

Fit a thermal probe

QS strongly recommends a temperature sensor (KTY83/122, KTY84/130 or a 10K NTC, model MF58-103F3950) so the controller can protect the motor from the inside. Set the matching type in the app or it does nothing.

Over-volting works, with a cost

A 3 kW motor doing 80 km/h at 72 V might reach 100 km/h at 96 V, with continuous output well past its 3 kW rating. QS calls this abusing usage: it runs, life is shorter, and V3/V4 handle it better than V2.

Hall plugs

V2 and V3 hub motors have two hall plugs — the second is a spare. If a hall reading goes bad, try the other plug before pulling the motor apart. V1 motors have only one.

Expected life

QS puts general usage at 2–5 years, 5–7 in good conditions. Testing and abuse shorten that, and heat is what does the damage — which is why the temp sensor and current ceilings matter more than any other setting.

Worked example — a QS165 v3 60H on 72 V

  1. Position sensor: Hall 120°.
  2. Pole pairs: from the motor's spec — a QS V3 hub is 16; a geared mid drive is not the same number, so check before you assume.
  3. Temp sensor: set to whatever is physically in the motor, or None.
  4. Rated voltage: 72 V.
  5. Rated power: 12,000 W from the listing.
  6. Max line current: start conservative — QS's own guidance is 70–80 A at 72 V for long life. Raise from there while watching motor temperature.
  7. Max phase current: below the controller's rating and below what the motor is happy with. Raise in 10–15% steps.
  8. Transmission ratio: this motor is 1:2.37 geared, so the speedo needs that ratio and the real pole-pair count to read correctly.
  9. Run self-learning with the wheel off the ground, then re-check the direction.