FarDriver Troubleshooting & Error Codes

Find troubleshooting guidance for common FarDriver controller problems, connection issues, motor faults and beep codes.

Read this first

These controllers push hundreds of amps. Always put the wheel off the ground before applying throttle during setup, disconnect the battery before touching phase or battery leads, and use a precharge resistor or a breaker with precharge when connecting the pack. Never plug or unplug a Bluetooth dongle with the controller powered on. Tuning past your motor's, battery's or BMS's limits can destroy hardware or start a fire — you're responsible for what you set. Big-power settings are for off-road and closed-course use.

JTroubleshooting

The problems that come up most, and what actually fixes them.

SymptomMost likely causesWhat to do
App can't find the controller Controller not powered · dongle not seated or dead · Location permission off · another phone still connected · too far away Key on and confirm the dongle's red LED is blinking. Grant Location permission on Android. Force-close the app on any other phone. Stand within a few feet.
Connects but no live data Wrong app version for that firmware · flaky dongle Try the other app (official ↔ Worthless Controls). If one reads data and the other doesn't, it's a software mismatch, not a hardware fault.
Motor won't turn at all Self-learning never run · wrong sensor type · wrong pole pairs · phase wires out of order · throttle thresholds wrong Set sensor type and pole pairs, then run self-learning. If it still won't spin, swap blue and green phase wires (or flip PhaseExchange) and repeat.
Motor runs backwards Direction setting · learned in reverse Flip the motor-direction parameter and power-cycle, or tap 11110000 on the brake lever.
Vibration, growl or resonance at low speed LM mismatched to the vehicle · AN wrong for the motor type Step LM down 22 → 16 → 14 → 12 → 11 → 8 → 5 and stop at the first clean value. Check AN matches the motor (0 surface-magnet hub, 8–16 embedded/mid-drive).
MOE / OVER fault under load Field weakening too deep · AN wrong · PID set mismatched to motor power Lower max speed toward rated speed, pull current percentages down at the top RPM points, and pick the PID row that matches your motor's power class.
Hall or AB15 error Hall wiring · failed sensor · encoder ppr or pole pairs wrong Check every pin at the sensor plug, test the halls with a motor/throttle tester, and confirm sensor type and pole pairs — the wrong pole-pair count throws this exact fault. If the sensors really are dead, see replacement sensors. FAIF 384/512 exists for motors prone to AB15.
Throttle alarm, or power cuts when you twist Thresholds wrong · throttle failing · lost-throttle protection tripping Re-read resting and full voltages and reset both thresholds. If resting voltage drifts, replace the throttle.
Speedo reads double, half, or nonsense Tyre size · transmission ratio · speed pulse · pole pairs Fix tyre numbers and ratio first (real pole pairs ÷ entered pole pairs), then trim with speed pulse. Or run the wheel-calibration wizard.
Display stays blank Wrong special frame or protocol · wrong pins · timing too fast Start at special frame 16 with byte option 3, then step 32, 48, 64… Try step 0.9 ms with a 144 ms interval. Confirm pin wiring (12-tube: PIN 13/18/9; older: PIN 3/9/10).
Cuts out under hard acceleration Undervoltage protection · BMS current limit · breaker tripping · sagging pack Watch live voltage during the pull. If it dives to the cutoff, the pack or BMS is the limit, not the controller — lower max line current or set a gentler undervoltage taper.
Loses power after a few minutes Thermal limiting on motor or controller Check temperatures live. Improve airflow or cooling, lower phase current, or raise the temperature start point only if the hardware can genuinely take it.
Regen grabs or trips the BMS Negative current coefficient too high · full pack · regen active at low RPM Back the coefficient toward −10%, zero regen at low RPM, and expect reduced regen on a freshly charged pack.
App asks for a password when saving Parameter lock set by the manufacturer or the bike's OEM Don't guess — repeated wrong entries can lock you out further. Ask whoever supplied the controller or the complete bike for the code.
Dongle died after working fine Plugged or unplugged while powered Replace it, and always key off first. Dongle sales are final.

Beep codes — what the controller is telling you

The controller reports faults by beeping. Count the beeps. More than one fault can be queued up, so listen for several different patterns in a row.

BeepsFaultWhat to do
1Motor hall faultCheck the hall sensor wires. If they're all seated and the fault stays, the hall sensors may need replacing. Very commonly caused by running the wrong pole pairs.
2Throttle failThe throttle has failed to operate — check the throttle and its thresholds.
3Amp protect restartOver or under amperage from the battery.
4Controller phase current protectThe controller can't make power for acceleration. Try increasing max phase current, or decreasing it if it's set beyond the motor.
5Voltage failureBattery too low or too high for the controller. Check the rated voltage setting.
6Security lock alarmReserved for the alarm system on larger vehicles.
7Motor over temp170 °C is the controller's ceiling, but don't run any motor above 70 °C. Check the right temp sensor type is selected.
8Controller over tempThe controller is too hot — improve airflow or cooling, or pull the current back.
9Phase current overflowThe controller is failing to make a strong acceleration — increase phase amps.
10Phase zero point currentThe controller failed to zero out.
11Phase wire short circuitInspect the large phase wires on both the motor and controller side for tears or chafing. Check every wire on the bike.
12Wire current zero point faultInternal controller fault. Don't use it — contact us.
13MOSFET upperUpper MOSFET damaged. Disconnect all wires from the controller and reattach.
14MOSFET lowerLower MOSFET damaged. Disconnect all wires from the controller and reattach.
15Over amp maxMore amps than Max Line Current allows for.

Normal startup

2 beeps when you power on. That's healthy.

Auto Learn armed

2 short beeps then 1 long — beep, beep, beeeeep. Now twist the throttle.

One long beep

Check whether the brake and throttle are both active at once. A working setup won't accelerate while the brake is pulled — that's the test.

2 short · pause · 1 short, repeating

Program verification failed. You're on an old app build — install the current version from the top of this guide.

4 short · 1 long · 5 short, repeating

Firmware applied by update doesn't match the controller. Check the files match the model on the controller's label.

Still stuck?

Post your controller model, motor, pack voltage and a screenshot of the live data screen in the group below — that's usually enough for someone to spot it in one reply. Or go straight to Ryan — Facebook Messenger or Ryan@econiccycles.com.