Independent technical resource

FarDriver Controller Settings Explained

Understand FarDriver controller parameters, including motor configuration, battery and phase current, throttle, speed, regen and protection settings.

Read this first

These controllers push hundreds of amps. Always put the wheel off the ground before applying throttle during setup, disconnect the battery before touching phase or battery leads, and use a precharge resistor or a breaker with precharge when connecting the pack. Never plug or unplug a Bluetooth dongle with the controller powered on. Tuning past your motor's, battery's or BMS's limits can destroy hardware or start a fire — you're responsible for what you set. Big-power settings are for off-road and closed-course use.

GEvery setting, in plain English

The app groups parameters into pages. Here's what each one does, sensible values, and which ones to leave alone. Values here follow our own FarDriver Tuning Guide v2.65 and FarDriver's PID documentation. Open a section to expand it.

Basic motor parameters — do these first
SettingWhat it doesValue / range
Position sensor (AngleDetect)Tells the controller how the motor reports position. Wrong choice = motor won't run.Hall 120°/60°, incremental encoder (4096 / 8192 ppr), differential encoder (2048–16384 ppr), absolute encoder
Pole pairsElectrical cycles per mechanical turn. Drives speed display and commutation. A wrong value is the most common cause of a hall fault.MY1020 3 · EC4P 4 · Sotion FW01/FW11/FW23/GTS11 5 · Kunray KR5V 5 · QS mid drives 5 · EGO mini bike stock hub 16. Full list below.
Temp sensorWhich sensor is in your motor. Auto Learn will not run until this is set correctly. Set None if the motor has no sensor.The app numbers them: 0-None · 3-KTY · 5-KTY · 6-NTC. Per-motor list below.
Phase shift (PhaseOffset)Commutation angle. This is what self-learning sets for you.0–360° (hub motors often land on 30°, 90° or 210°)
Motor directionWhich way is forward.0 = sprocket right, 1 = sprocket left (needs a save + power cycle)
Rated voltageYour pack's nominal voltage. Everything else scales off it. Cannot be set above the controller's rating.48 / 60 / 72 / 75 / 84 / 96 / 108 V
Rated speed (RPM)Motor speed at rated voltage. Base for field weakening maths.From the motor spec, or learned
Rated powerMotor nameplate watts. Display and protection only.Watts
Max speedThe speed ceiling. The gap above rated speed is your field-weakening depth.Weakening % = (Max − Rated) ÷ Rated × 100
Max phase currentTorque. The big one. Never above the controller's factory number.Amps — raise slowly
Max line currentYour battery's maximum continuous discharge — not its peak, burst or pulse rating. During the first Auto Learn, limit it to match the motor's spec.Max power = pack volts × line amps
Swap phase wires (PhaseExchange)Software version of swapping blue and green.0 = normal, 1 = swapped
Weak magnetic responseHow fast field weakening comes in.0–6 or None. "Fast" is the general default; "medium" reduces jitter at high speed; slow risks overcurrent
Field-weakening depth limits

Surface-magnet motors (most hub motors): keep weakening depth under about 50%. Interior/embedded-magnet motors tolerate up to roughly 150%. Going deeper is how people find MOE and OVER faults — and melted magnets.

Throttle calibration — the fix for jumpy or dead throttle

The controller needs to know your throttle's real voltage span. Read the live throttle voltage in the app with the throttle closed, then wide open, and set the thresholds around those readings.

Throttle typeResting voltageSet low thresholdFull voltageSet high threshold
Motorcycle / thumb throttle0.8–0.9 V1.1 V4.1–4.3 V3.9 V
12 V foot pedal0–0.2 V0.5 V4.6–4.8 V4.3 V
  • Rule of thumb: set the low threshold 0.10–0.15 V above the resting throttle voltage. That kills the dead spot without the motor creeping.
  • Set the high threshold a little below the real full-throttle voltage so you can actually reach 100%.
  • Anything more than 0.6 V above the high threshold triggers a throttle-fault alarm — that's the safety net for a shorted throttle.
  • Newer firmware (v742+) can learn the throttle span automatically during self-learning.
Throttle feel — acceleration & deceleration steps
SettingWhat it doesTypical
Acceleration sensitivityHow fast the controller chases the throttle. Higher = snappier and harder on the drivetrain.16–32 mellow · 64–128 sporty · up to 224 track
Deceleration sensitivityHow fast power drops when you roll off. Higher = less lag.16–224
Throttle profileShape of the throttle map.Linear · Sporty · Economical
Field-tested trick

Set the deceleration step slightly higher than the acceleration step. You get a clean, predictable roll-off without the drivetrain snatching on the way back on.

Gears — Boost / High / Mid / Low
GearShown asCurrent source
BoostBstFactory maximum line + phase current, plus the limiting curve. Momentary button.
HighDYour set max line + phase current, limiting curve and speed limit.
MediumDMMid-gear line/phase percentages and mid RPM limit.
LowDLLow-gear line/phase percentages and low RPM limit.

Each gear has its own line current ratio, phase current ratio and RPM limit, expressed as a percentage of the high-gear numbers. A useful street setup: Low around 30–40% for tight, technical or wet riding, Mid around 60–70%, High as your real tune, Boost for the odd pull.

Gear selection modes range from single-speed through push-button up/down, tap 2-speed, 3-speed and 4-speed, to CAN/serial control — set the mode, then assign the switch to a function pin. A 3-speed switch or a throttle with a boost button plugs straight in.

Current limiting by RPM — the power curve

This is a table of "percentage of current allowed" at a list of RPM points (500, 1000, 1500, 2000, 4000, 5000, 5500, 6000, 6500, 8000, 8500, 9000). It's how you stop the controller shoving full current into a motor that's already spinning past its comfortable speed. In Worthless Controls this is the visual power-curve editor.

Those RPM numbers are electrical, not wheel RPM

They're scaled by the pole-pair value you entered. With a 16 pole-pair hub motor and pole pairs set to 4, the table's "4000" is really 1000 wheel RPM, "6000" is 1500, "8000" is 2000. Work out your own scale before you edit the curve.

  • Shallow weakening (~50% depth): around 30% current at the 6000 point, under 5% above 6500.
  • Deep weakening (100%+ depth, embedded-magnet motors): can hold over 70% at 8000, ~30% at 8500, under 5% at 9000.
  • Always come up from safe values. If MOE or OVER trips, you went too far too fast.
Regen / eABS — braking that puts charge back
SettingWhat it doesTypical
Brake currentSteady regen current when braking or rolling off.5–20 A (2-wheel) · default 2 A
Max brake currentPeak regen during hard braking.10–40 A (2-wheel) · default 4 A
Throttle-return brake pointHow much regen you get just from closing the throttle.0 = strongest off-throttle braking
Negative current coefficientOverall regen strength as a percentage.Start at −10%, work toward −30%
Don't jump straight to −50%

Regen that strong locks the wheel on loose surfaces and can spike your pack voltage. Increase it in small steps and test each one. Also zero out regen at very low RPM so it doesn't grab when you're paddling around the pits.

A charged pack has nowhere to put regen energy — if your BMS trips or you see overvoltage right after a full charge, that's why, not a fault.

Protection — voltage, temperature, throttle
PackLow Vol Protect — suggestedController's own floor
48 V39.1 V42.0 V
60 V51.1 V52.5 V
72 V (20s)63.1 V63.0 V
84 V—73.5 V
96 V—84.0 V
108 V—94.5 V
  • Undervoltage response: choose how far above the cutoff power starts tapering (+2 V, +4 V, +8 V, +12 V, +16 V), or taper by state of charge (5–10%), or let a CAN BMS dictate the limit. Tapering is much nicer than a hard cut mid-corner.
  • Overvoltage, motor temp and controller temp protection are set internally from the rated voltage and aren't user-adjustable.
  • Temperature control start point: begin limiting at 50°C (longest hardware life), 70°C (balanced) or 80°C (maximum performance, shortest life, trips easily on hard launches).
  • Lost throttle alarm: leave enabled. It's what stops a disconnected throttle from becoming a runaway.
  • Turtle / limp-home current = your max phase current × turtle factor ÷ 2048 (factor defaults to 53).
PID and motor matching — AN, LM, KI/KP Advanced
Wrong values here burn controllers

PID governs the current loop. Mismatched numbers cause MOE, OVER and PHASE faults, poor starting efficiency, or a dead controller. Change one thing at a time and write down what it was.

AN — motor body type (0–16): hub motors are BLDC — set 0, and never above 4. Embedded or interior-magnet mid drives are 8 or more; IPMSM motors and automotive PM motors use 16. FarDriver's own worked example: a QS138 90H V1 IPMSM, 5 pole pairs, runs AN 10. Set it wrong and you get poor starting efficiency and MOE warnings.

LM — vehicle matching (5–22): default 22, electric default 18, small tricycles under 10. If there's no vibration at 22, leave it alone — some motors are smooth at 22 and get worse when you lower it. If you do get jitter or resonance at low or mid speed, step down 22 → 16 → 14 → 12 → 11 → 8 → 5 and stop at the first value where it clears; prefer the larger number. If it's still there at 5, the problem isn't LM — put it back to 22. Too low and the controller can't hold the current, which brings MOE/OVER protection and can burn the controller.

KI / KP sets: higher-power, higher-voltage motors want smaller numbers. Pick a whole row, not individual values:

StartKIMidKIMaxKIStartKPMidKPMaxKPSuits
111101010Surf board default
223202030Super-high-power motor
334303040—
446404060High power default
458405080—
669606090Medium power motor
67106070100—
88128080120Small / medium power default
89138090130—
8101580100150—
8111680110160—
101218100120180—
101319100130190—
101421100140210—
101522100150220—
161624160160240Low-power machine

SKI / SKP tune the speed loop: SKI 1–18 (heavy vehicles 18, light 2, default 9), SKP 5–20 (default 10). MOE protection stays ON — there is no good reason to disable it.

Speedometer, tyre size and displays

A speedo that reads double or half is almost always one of these four:

  1. Tyre numbers. For a 120/70-R12: width 120, aspect ratio 70, diameter 12.
  2. Transmission ratio. Real motor pole pairs ÷ the pole-pair value you entered. A 20 pole-pair hub with pole pairs set to 4 gives a ratio of 5.
  3. Speed pulse (1–31) — higher makes the meter read higher.
  4. Velocity pulse base — around 40,459 for hub motors, 26,043 for mid-drives.

Worthless Controls has a wheel-calibration wizard that walks this for you.

Display protocols: most single-wire dashes work on special frame 16 with byte option 3; if the dash stays blank, step the special frame 16 → 32 → 48 → 64 and so on, and try step length 0.9 ms with a 144 ms interval. CAN displays use CAN command 60 on H-series with a 150 ms detection delay. Check which pins your dash uses: 12-tube controllers usually PIN 13/18/9, older ones PIN 3/9/10.

Displays that are known to work →

Battery gauge calibration

Pick the battery signal source that matches your build: single-wire dash, serial BMS, CAN BMS (best if you have it), or a simulated curve for Li-ion, lead-acid or LiFePO₄.

Then calibrate the two ends: with the pack at roughly 10% left, adjust the zero-capacity factor until the gauge reads 10%; on a full pack, adjust the full-capacity factor until it reads 100%.

Function pins — cruise, reverse, park, anti-theft, boost

Features only work once you assign them to a physical input pin. Depending on the controller the choices are PIN 2, 3, 5, 8, 9, 14, 15, 17, 18 and 24.

FunctionWhat it gives you
BoostMomentary full-factory-power button
CruiseHolds a steady speed
P (park)Electronic park brake — can auto-return after an idle timeout (default 10 s)
Forward / reverseDirection switch, with its own reverse RPM limit
High / low speedThe gear switch input
Charging protectionBlocks drive while the charger is plugged in
Anti-theftImmobiliser — high-resistance mode (hard to push, no battery drain) or locked-motor mode
Seat / kill switchCuts or limits drive when nobody's on it
Speed limiterCaps top speed on demand

Brake modes: normal (throttle cuts on brake), floating, floating-disconnect, floating + auto P release, or power-off. Both brake lines should read floating when the lever is released.

Hill hold / descent control: hold on a slope in neutral or P and creep down under control when you release the throttle. Response 1–7 — lower values creep back more but are smoother, higher values lurch forward less predictably.

Speed-limit release: some controllers ship speed-limited. A six-digit Morse code on the brake lever unlocks it; 000000 means no restriction. A seventh digit makes the state stick across power cycles.