Sotion FW23S Encoder FarDriver settings
Motor matching, battery requirements, current ceilings, pole pairs and temperature sensor for Sotion FW23S Encoder.
Motor identification photo

Sotion manufacturer reference

Sotion labels FW23S 7 kW / 14 kW and lists Hall and encoder options for Tuttio/Kugoo. This agrees with the earlier Econic power listing; the image shows the family, not the sensor type.
Manufacturer labels are separate from our experience-based tuning ceilings. The app's 6-NTC10K setting comes from the site owner's motor reference, not confirmation in this product listing.
These figures are reference ceilings, not safe starting settings or certified continuous ratings. Verify exact controller revision, motor winding, sensor, battery/BMS, full-charge voltage, wiring, cooling and thermal protection. Start conservatively, secure the driven wheel off the ground and monitor temperatures. Do not operate with unverified thermal protection.
FarDriver app settings
| Pole Pairs | 5 |
|---|---|
| Temp Sensor | 6-NTC10K |
| Position sensor | Encoder |
| Angle Detect | Encoder 4096 |
| Nominal voltage reference points | 48, 72 V |
| Battery discharge reference | 100–150 A typical; 200 A required for full 48 V target |
Voltage-specific tuning reference
| 48 V | 200 A line / 450 A phase |
|---|---|
| 72 V | 150 A line / 360 A phase |
Candidate controllers
Voltage and sensor compatibility must be checked individually.
Motor-specific notes
Smaller, less power-hungry alternative to FW23; upgraded 200 A battery required for 48 V full target.
Match this motor Motor photo directory
View corresponding model or noted variant at E-Conic Cycles ↗
Original retailer technical reference
Disconnect the battery before wiring. Verify pin assignments, voltage and hardware revision against the supplied diagram. Maximum controller ratings are not safe tuning targets. Set limits for the battery, BMS, motor and cooling system; secure the vehicle with the driven wheel off the ground for initial tests.
| Parameter | Reference value |
|---|---|
| Rated / peak power | 7 / 14 kW |
| Pole pairs | 5 |
| Temperature sensor | NTC10K |
| Angle Detect | Encoder 4096 |
| Sprocket | 420 12T |
| Listed controller pairings | ND72300b / ND72450b |
Setup checks
Use an encoder-compatible controller, not a hall-only version. Rated motor power is not a recommended controller power limit. Confirm the battery and BMS limits before self-learning and tuning.
Technical references
Retailer-listed specifications, reviewed November 24, 2026. Confirm the exact hardware revision before installation.
Related guides
Controller specification references
Check the exact candidate’s nominal voltage, line and phase ratings and feedback type before choosing hardware.
Encoder connector safety
If your FW23S uses encoder feedback, never disconnect or reconnect the encoder with power applied. Isolate the battery and confirm the correct pinout and supply before servicing. Do not copy a Hall connector recovery method. See encoder handling precautions.