FarDriver battery requirements: continuous, burst and line current
Learn how battery and BMS continuous discharge, burst ratings, full-charge voltage and FarDriver line current affect controller selection.
Line current versus phase current
Line current is battery-side current. Phase current is motor-side current and is not the same as battery discharge. A controller with a large phase-current rating does not mean a battery can supply that number of amps. The two limits must be set separately.
Continuous and burst discharge
Use the battery pack and BMS manufacturer’s continuous discharge rating, not the cell rating alone. Burst discharge is available only under specified conditions for a limited duration; verify duration, temperature, wiring, fuses and connector ratings. Use the lowest applicable continuous rating when setting sustained line current.
Verify fully charged voltage
Nominal voltage is a class, not a maximum. Obtain the actual fully charged pack voltage from the pack manufacturer, verify the controller’s exact absolute voltage limit and allow for regenerative braking voltage rise. A nominal-class match alone is not enough. For 108 V projects, use our Moxin referral.
Choose a controller
Start with the battery-first finder. Select the sensor type, compare current ratings, then use the motor matching tool to check the recorded motor current ceilings and temperature sensor. Confirm hardware documentation before any installation.
Why a FarDriver e-bike loses power under load
Battery voltage sag, BMS limits, connector resistance and controller thermal derating can reduce torque even when the motor spins quickly without load. Review existing telemetry and verified component limits before modifying settings. Slow under load troubleshooting.
Battery and BMS current protection thresholds and delays
Do not treat a battery's advertised peak discharge rating as continuous output. A BMS may have multiple discharge-current thresholds, warning levels and time delays, as well as separate charge-current and short-circuit protections. A lower or faster-acting threshold can interrupt a load before an advertised peak duration is reached. Mini Me's ANT BMS example illustrates why the actual programmed limits need to be checked against the battery supplier's specifications.
Set FarDriver line current no higher than the verified continuous limits of the battery, BMS, connectors and wiring. Do not increase BMS protection settings, extend fault delays or bypass protections to match a controller rating. Phase current is motor-side current and cannot be calculated using a universal multiplier of line current. Boost timers and gear ratios do not override hardware ratings.
Regeneration requires verified battery charge acceptance and BMS charge-current limits, including near full charge. If the BMS cuts out, diagnose the cause with the battery supplier rather than relaxing its protections. Record actual voltage, temperature and fault information and seek support where needed.