Sotion FW23 Encoder FarDriver settings
Motor matching, battery requirements, current ceilings, pole pairs and temperature sensor for Sotion FW23 Encoder.
Motor identification photo

Sotion manufacturer reference

Manufacturer lists a 72 V splined-shaft FW23 for Tuttio/Kugoo, with Hall and encoder options. Its encoder kit is labeled 72 V / 8 kW. Verify shaft and sensor variant; the image is a family photo.
Manufacturer labels are separate from our experience-based tuning ceilings. The app's 6-NTC10K setting comes from the site owner's motor reference, not confirmation in this product listing.
These figures are reference ceilings, not safe starting settings or certified continuous ratings. Verify exact controller revision, motor winding, sensor, battery/BMS, full-charge voltage, wiring, cooling and thermal protection. Start conservatively, secure the driven wheel off the ground and monitor temperatures. Do not operate with unverified thermal protection.
FarDriver app settings
| Pole Pairs | 5 |
|---|---|
| Temp Sensor | 6-NTC10K |
| Position sensor | Encoder |
| Angle Detect | Verify encoder resolution and app option |
| Nominal voltage reference points | 48, 72, 76 V |
| Battery discharge reference | 48 V: 250 A; 72/76 V: 230 A |
Voltage-specific tuning reference
| 48 V | 190 A line / 400 A phase |
|---|---|
| 72 V | 190 A line / 400 A phase |
| 76 V | 190 A line / 400 A phase |
Candidate controllers
Voltage and sensor compatibility must be checked individually.
Motor-specific notes
High-performance Tuttio drop-in and compact rectangular direct-drive housing for custom builds; multiple colors.
Match this motor Motor photo directory
Controller specification references
Check the exact candidate’s nominal voltage, line and phase ratings and feedback type before choosing hardware.
Never disconnect or reconnect an encoder with controller power on
Live unplugging or reconnecting can damage an encoder, including the Sotion FW23 encoder variant. Isolate the battery and follow the supplier’s discharge and verification procedure before touching feedback connectors. Confirm the exact pinout and sensor supply before reconnecting. Do not apply Hall connector troubleshooting or Force Unbind connector checks to an encoder motor.
Hall vs. encoder compatibility · Binding recovery precautions · Get technical assistance