FarDriver Help

FarDriver ND72680b Encoder / BT72680b controller specifications

Encoder only · flat or finned heatsink

Compare this controller Check against my battery

Operating voltage48–72 V
Max line current350 ABattery side
Max phase current680 AMotor side

Listed controller maximums, not recommended tuning settings or guaranteed continuous output.

ND72680b Encoder / BT72680b controller listing photoView controller at E-Conic Cycles ↗
Blue flat-bottom encoder listing photo; older external dongle configuration shown. Photo: E-Conic Cycles. Existing photo retained; direct CDN recheck not completed.
Safety and compatibility

Disconnect the battery before wiring. Verify pinouts, voltage and hardware revision. Secure the vehicle with its driven wheel off the ground during initial testing.

Physical specifications and key differences

Dimensions: Black finned: 189 × 120 × 58 mm; 20 mm heatsink

Stock Tuttio, QRonge and Tasaca display/throttle assemblies are not plug-and-play. The black finned Tuttio installation uses a slotted mount; check the bracket for the exact housing.

Motor and battery matching

Sotion FW26x1 (QRonge X1 Spark)

10 kW rated / 20 kW peak; 5 pole pairs; NTC10K; Encoder 4096. Econic advises an upgraded battery with more than 150 A line capability for this build, not a universal controller setting.

Motor source at E-Conic Cycles

Battery requirements

Voltage: select a compatible nominal pack within the listed 48–72 V range and confirm full-charge voltage against the controller's absolute input limit.

Discharge capability: for a 350 A battery-current setting, the cells, BMS, wiring, fuse and connectors must all support that current for the intended duration. A lower-rated battery can be used only with appropriately reduced current limits and verified compatibility. Do not use the phase-current rating to size a battery.

Capacity (Ah): select for range, load and cell discharge rating; no universal minimum Ah is implied by this controller.

Before tuning

Set MaxLineCurr to the lowest verified battery-side limit, and MaxPhaseCurr to a safe motor/controller limit. Verify thermal management, voltage protection and regenerative charging limits. These are selection principles, not a validated build prescription.

Site-owner suggested motor pairings

Check voltage, sensor, battery and hardware revision before use.

Calculate controller-limited reference ceilings

Technical reference

Retailer listing checked November 24, 2026. Confirm label, sensor, cooling and harness revision before purchase.

E-Conic Cycles — exact product listing

Compare similar model names

ND72680 hall