Sotion FW26x1 Encoder FarDriver settings
Motor matching, battery requirements, current ceilings, pole pairs and temperature sensor for Sotion FW26x1 Encoder.
Motor identification photo

Sotion manufacturer reference

Sotion currently displays 10 kW / 20 kW, agreeing with the Econic reference, but other Sotion catalog results and the product URL show 12 kW / 25 kW. Confirm the exact revision with the supplier. Both sensor options are listed; this page covers the encoder version only.
Manufacturer labels are separate from our experience-based tuning ceilings. The app's 6-NTC10K setting comes from the site owner's motor reference, not confirmation in this product listing.
These figures are reference ceilings, not safe starting settings or certified continuous ratings. Verify exact controller revision, motor winding, sensor, battery/BMS, full-charge voltage, wiring, cooling and thermal protection. Start conservatively, secure the driven wheel off the ground and monitor temperatures. Do not operate with unverified thermal protection.
FarDriver app settings
| Pole Pairs | 5 |
|---|---|
| Temp Sensor | 6-NTC10K |
| Position sensor | Encoder |
| Angle Detect | Encoder 4096 |
| Nominal voltage reference points | 48, 60, 72, 76 V |
| Battery discharge reference | 200 A |
Voltage-specific tuning reference
| 48 V | 175 A line / 400 A phase |
|---|---|
| 60 V | 175 A line / 400 A phase |
| 72 V | 175 A line / 400 A phase |
| 76 V | 175 A line / 400 A phase |
Candidate controllers
Voltage and sensor compatibility must be checked individually.
Motor-specific notes
QRonge Spark X1 fitment. Encoder 4096 per reviewed listing.
Match this motor Motor photo directory
View corresponding model or noted variant at E-Conic Cycles ↗
Original retailer technical reference
Disconnect the battery before wiring. Verify pin assignments, voltage and hardware revision against the supplied diagram. Maximum controller ratings are not safe tuning targets. Set limits for the battery, BMS, motor and cooling system; secure the vehicle with the driven wheel off the ground for initial tests.
| Parameter | Reference value |
|---|---|
| Rated / peak power | 10 / 20 kW |
| Pole pairs | 5 |
| Temperature sensor | NTC10K |
| Angle Detect | Encoder 4096 |
| Sprocket | 420 10T |
| Listed controller pairings | ND72450b / ND72680b |
Setup checks
Use an encoder-compatible controller, not a hall-only version. Rated motor power is not a recommended controller power limit. Confirm the battery and BMS limits before self-learning and tuning.
Technical references
Retailer-listed specifications, reviewed November 24, 2026. Confirm the exact hardware revision before installation.
Related guides
Controller specification references
Check the exact candidate’s nominal voltage, line and phase ratings and feedback type before choosing hardware.