Compact liquid-cooled C1000 ratings, harness and installation considerations.
Compare this controller Check against my battery
View controller at E-Conic Cycles ↗Disconnect the battery before wiring. Verify pin assignments, voltage and hardware revision against the supplied diagram. Maximum controller ratings are not safe tuning targets. Set limits for the battery, BMS, motor and cooling system; secure the vehicle with the driven wheel off the ground for initial tests.
| Parameter | Reference value |
|---|---|
| Voltage | 48–72 V |
| Line / phase maximum | 500 A / 1,000 A |
| Dimensions | 189 × 120 × 59 mm |
| Harness | Gen 2 |
| Cooling | Integrated liquid cooling |
Revision-specific setup
The C1000 shares a designation with other YCK072500 products but is a different physical configuration. The retailer documents special restoration settings for its early test batch. Confirm firmware and follow the exact source instructions rather than applying those settings to other controllers.
Motor and battery matching
Motor selection
No specific named motor pairing is confirmed by the reviewed listing. Match motor sensor type, voltage, manufacturer current limits, thermal limits and physical installation. Check the exact controller label and motor data before buying.
Motor specification reference · Hall vs encoderBattery requirements
Voltage: select a compatible nominal pack within the listed 48–72 V range and confirm full-charge voltage against the controller's absolute input limit.
Discharge capability: for a 500 A battery-current setting, the cells, BMS, wiring, fuse and connectors must all support that current for the intended duration. A lower-rated battery can be used only with appropriately reduced current limits and verified compatibility. Do not use the phase-current rating to size a battery.
Capacity (Ah): select for range, load and cell discharge rating; no universal minimum Ah is implied by this controller.
Set MaxLineCurr to the lowest verified battery-side limit, and MaxPhaseCurr to a safe motor/controller limit. Verify thermal management, voltage protection and regenerative charging limits. These are selection principles, not a validated build prescription.
Compare the conventional ND721000 / YCK072500 housing before selecting parts.
Technical references
Retailer-listed specifications, reviewed November 24, 2026. Confirm the exact hardware revision before installation.