FarDriver ND721000 / YCK072500 controller specifications

Hall family · conventional housing

Compare this controller Check against my battery

Operating voltage48–72 V
Max line current500 ABattery side
Max phase current1,000 AMotor side

Listed controller maximums, not recommended tuning settings or guaranteed continuous output.

ND721000 / YCK072500 controller listing photoView controller at E-Conic Cycles ↗
Model-label match — ND721000, 500 A / 1000 A; external dongle pictured.
Safety and compatibility

Disconnect the battery before wiring. Verify pinouts, voltage and hardware revision. Secure the vehicle with its driven wheel off the ground during initial testing.

Physical specifications and key differences

Dimensions: 189 × 136 × 56 mm; 14 mm heatsink

Flat-bottom and integrated liquid-cooled options have been listed. This is distinct from the compact C1000 even though both use the YCK072500 designation. Verify the exact housing, harness and cooling arrangement.

Motor and battery matching

Motor selection

No specific named motor pairing is confirmed by the reviewed listing. Match motor sensor type, voltage, manufacturer current limits, thermal limits and physical installation. Check the exact controller label and motor data before buying.

Motor specification reference · Hall vs encoder

Battery requirements

Voltage: select a compatible nominal pack within the listed 48–72 V range and confirm full-charge voltage against the controller's absolute input limit.

Discharge capability: for a 500 A battery-current setting, the cells, BMS, wiring, fuse and connectors must all support that current for the intended duration. A lower-rated battery can be used only with appropriately reduced current limits and verified compatibility. Do not use the phase-current rating to size a battery.

Capacity (Ah): select for range, load and cell discharge rating; no universal minimum Ah is implied by this controller.

Before tuning

Set MaxLineCurr to the lowest verified battery-side limit, and MaxPhaseCurr to a safe motor/controller limit. Verify thermal management, voltage protection and regenerative charging limits. These are selection principles, not a validated build prescription.

Site-owner suggested motor pairings

Check voltage, sensor, battery and hardware revision before use.

Calculate controller-limited reference ceilings

Technical reference

Retailer listing checked November 24, 2026. Confirm label, sensor, cooling and harness revision before purchase.

E-Conic Cycles — exact product listing

Compare similar model names

C1000 compact

Related guides

Compare controller models · Wiring harnesses · Tuning · Precharge

QF721000 + CANBUS bundle bundle

Special buy — Sotion SDP-2 5" display, throttle & mounts (Yozma / Valtinsu). The catalogue lists 500 A line and 1000 A phase. Check exact CANBUS protocol and included parts; the bundle is not a different verified controller tune.